Floor Slab Cross Section

Column with z cross section 700x650x600x250x250x250 mm.
Floor slab cross section. 13 2 4 the relative restraint provided by the torsional resistance of the effective transverse edge beam is reflected by parameter βt such as. Cad block of composite steel deck floor. 2 cb t cs s ec ei β where ecb muduls of elasticity of beam concrete c torsional. Outer and inner leafs brickwork walls cavity insulation wall ties air space natural stone facing roof and floor sections and drain pipe.
The insulation phase is crucial for a radiant floor. You will also need some type of steel reinforcing in the garage floor slab portion similar to what is described above in the type 1 garage foundation. X 27 in interior beam dimensions 14 in. Microsoft powerpoint 1 0 2016 sog seminar cross section of a floor ad.
Two way concrete floor slab with beams design and detailing. Base floor slab waterproof system a typical base floor slab where the design criteria include controlling moisture migration and water vapor transmission into the interior space can be referred to as a waterproof. Once the contractor has been appointed the k value is to be site checked in accordance with the following clauses. X 18 in edge beam dimensions 14 in.
To cross one tube over another during tubing layout notice how this simple configuration places each loop within its neighbor starting from the outer connections of the. Beams cross section to be considered in calculating ib1 and ib2 are shown below. Slab design is to be based upon this value when preparing tender prices. The suspended reinforced concrete slab is tied into the external capping beam.
Steel deck profiled steel sheeting steel beam or joist cast in situ concrete topping top reinforcement mesh bottom reinforcement and stud shear connectors. Finite elements 1 st example 2 nd example. The concrete floor slab itself provides structural support for floor loads and suitable backup for floor coverings and finishes. Alternative floor slab detail.
Modelling slabs frame behaviour in regions of columns deflection of beams torsional stiffness of beams. Two way concrete floor slab with beams design and detailing. Design the slab system shown in figure 1 for an intermediate floor where the story height 12 ft column cross sectional dimensions 18 in. Wall section drawing include details like.
The large scale detail below shows a cross section through the perimeter of the type 2 garage foundation giving dimensional details and the general placement of reinforcing steel and anchor bolts. Cross section of composite slab composed of. X 20 in and unfactored live load 100 psf. The reinforced concrete floor slab is kept free of the perimeter walls.
Cavity wall construction detail cross section.