Floor Load Width Diagram

Figure ta 2 14 load diagram for girder bc.
Floor load width diagram. Area 0 5 sqrt l 1 2 l 2 2 w c. Beam uniform load floor loading psf x tributary width ft beam b 3 6 8 tributary width. Supporting load bearing walls and lintels in lower storey load bearing walls. Determination of roof load width.
A room used solely for sleeping might need to carry only 30 psf whereas a garage floor over a basement would need 50 psf or higher. Alternately you can find w c by recognizing that the load on the girder has a triangular distribution and then set up the expression that equates the tributary load to the shape of the load diagram. In order to use the table select the floor load width from among the top line of the table in this case 1200mm 1800mm etc our example is 2m 2000mm and use the corresponding column 2400mm below to select the appropriate size of bearer from the list on the left and the post spacing measurement to match from within the column. Maximum floor joist span for no.
For an internal bearer which i assume you aren t after it is the half span load in both directions. 8th sep 2011 03 37 pm. 1 ft 0 3048 m. This is the fourth video in the series on the timber framing code.
Dead load weight of structure and fixed loads 10 lbs ft 2. Beam b 3 6 8 tributary width tributary area 18 ft 6 67 ft 120 ft2 tributary area beam span length x tributary width. An inaccessible attic space on the other hand might have a live load of only 20 psf. This results in the load diagram given in figure ta 2 14.
But a single span of 3800 with a flw of 2400 and joist spacings at 450 no roof loads you could get away with 1 x 240x45 f27 kiln dried hardwood. 1 psf lb f ft 2 47 88 n m 2. Flw is used to calculate the sectional size of. To calculate your bearer size accurately flw needs to be taken into account as well as the live load of thr floor.
First floor live loads have higher requirements than second floor live loads 40 pounds per square foot vs. 2 grade of douglas fir are indicated below. Where the bearer supports load bearing walls the type of roof covering also needs to be determined. Live load is weight of furniture wind snow and more.
Roof load width rlw and floor load width flw can be determined from as1684 or from the images below. Tile roofs impart a heavier dead load on the bearers than sheet roofs. This is referred to as the floor load width flw. Refer to figure 3 4 4 1 table a of the building code of australia.
The bearer span non loadbearing single or continuous is determined from the floor load width flw which for an external bearer will be half the joist span. This video looks at floor load width flw.